Electronic Switch
Electronic switch for micro interruptions in
supply and ground lines up to 100 A.
The Electronic Switch TOE 9261 is the first choice for generating
short interruptions in supply voltages and therefore ideally
suitable for testing vehicle electrics according to standards.
Depending on the model, currents up to 100 A can be switched at a
rated voltage of up to 60 V.
While testing vehicle electric power systems according to standards,
it is necessary to momentarily interrupt supply voltages.
Using the Electronic Switch TOE 9261, switching operations between <
10 μs and nearly unlimited duration are possible without
problem. Any voltage source of up to 60 V with appropriate
current rating provides the supply voltage. Using an external
signal generator, the current flow can be interrupted using
switch S1. Discharging the load circuit is possible during the
interruption of the load current by using another internal
switch S2. In addition, a configuration can be selected for
interrupting the negative return line of the load (ground
interruptions). Four signal line switches (S3 – S6) additionally
enable precise switching and interruption of signal and control
lines in any current flow direction. Control of these switches
is synchronous with S1.
Electronic switch for micro interruptions in
supply and ground lines up to 100 A.
The Electronic Switch TOE 9261 is the first choice for generating
short interruptions in supply voltages and therefore ideally
suitable for testing vehicle electrics according to standards.
Depending on the model, currents up to 100 A can be switched at a
rated voltage of up to 60 V.
While testing vehicle electric power systems according to standards,
it is necessary to momentarily interrupt supply voltages.
Using the Electronic Switch TOE 9261, switching operations between <
10 μs and nearly unlimited duration are possible without
problem. Any voltage source of up to 60 V with appropriate
current rating provides the supply voltage. Using an external
signal generator, the current flow can be interrupted using
switch S1. Discharging the load circuit is possible during the
interruption of the load current by using another internal
switch S2. In addition, a configuration can be selected for
interrupting the negative return line of the load (ground
interruptions). Four signal line switches (S3 – S6) additionally
enable precise switching and interruption of signal and control
lines in any current flow direction. Control of these switches
is synchronous with S1.