MPI-540-PV Solar

- Includes MPI-540-PV Solar multi-function meter, IRM-1 solar radiation and temperature meter, PVM-1 PV adapter, C-PV clamp, test leads and other accessories
- MPI-540-PV multifunctional meter of electrical and installation parameters created for measuring parameters of photovoltaic installations
- IRM-1 measures solar radiation values as well as panel and ambient temperatures
MPI 540-PV

- The largest touch screen on the market (7”) – remarkable ergonomics and ease of use
- Removable microSD memory card – easy increase of memory capacity
- Li-Ion battery – longer operation of the meter
- Measurement of photovoltaic installations according to EN 62446 standard
- Cooperation with solar radiation and temperature meter
MPI-540 + EVSE-01

- Testing home and industrial electrical installations
- Measurements of electric vehicle charging stations – quickly and in accordance with applicable regulations
- Measurements in the field of electric shock protection
- To facilitate diagnostics, one of the Sonel EVSE-01 sockets is provided with pulse width modulation signal (PWM).
MPI-536

- Measurement of insulation resistance using test voltage of 2.5 kV
- Visualization of RISO in the form of a graph
- The largest touch screen on the market (7”) – remarkable ergonomics and ease of use
- Removable microSD memory card – easy increase of memory capacity
MPI-540

- The largest touch screen on the market (7”) – remarkable ergonomics and ease of use
- Removable microSD memory card – easy increase of memory capacity
- Li-Ion battery – longer operation of the meter
- Three-phase power recorder – advanced power quality diagnostics
MPI-535

- The largest touch screen on the market (7”) – remarkable ergonomics and ease of use
- Removable microSD memory card – easy increase of memory capacity
- Li-Ion battery – longer operation of the meter
- Fast path from measurements to report – time saver
MPI-530

- Impedance measurement with resolution 0,001 Ω and 23 A current (44 A phase-to-phase) – short-circuit resistor RZW=10 Ω,
- Measurement range: 95…440 V, frequency 45…65 Hz,
- Measurement of short circuit loop impedance with resolution 0,01 Ω, in protected systems without tripping the RCD’s with IΔn ≥ 30 mA,
MPI-530-IT

- Measurement of short circuit loop impedance ZL-PE, ZL-N, ZL-L
- Test current: 23/40 A; measuring range acc. to IEC 61557: 0,13…1999,9 Ω
- Measurement of short circuit loop impedance ZL-PE in RCD mode
- Test current: 15 mA, measuring range acc. to IEC 61557: 0,50…1999 Ω
MPI-525

- Short-circuit loop measurement: impedance measurement with 23 A current (44 A phase-to-phase) – short-circuit resistor R=10,
- Short-circuit loop measurement: measurement range: 95…440 V, frequency 45…65 Hz,
- Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA.
MPI-520

- Short-circuit loop measurement: impedance measurement with 23 A current (44 A phase-to-phase) – short-circuit resistor R=10 Ω,
- Short-circuit loop measurement: measurement range: 95…440 V, frequency 45…65 Hz,
- Short-circuit loop measurement with resolution 0,01 Ω, in distribution network without tiggering RCD (IΔn≥30 mA): automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,
MPI-520S

- Short-circuit loop measurement: impedance measurement with 23 A current (44 A phase-to-phase) – short-circuit resistor R=10 Ω,
- Short-circuit loop measurement: measurement range: 95…440 V, frequency 45…65 Hz,
- Short-circuit loop measurement with resolution 0,01 Ω, in distribution network without tiggering RCD (IΔn≥30 mA): automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,
MPI-507

- Measurement of short circuit loop impedance in networks with rated voltage: 220/380 V, 230 V/400 V, 240/415 V and frequency 45…65 Hz, operating voltage range: 180…460 V
- Testing of prompt, short-delay and selective RCDs with rated current values 10, 15, 30, 100, 300, 500 mA
- Earth resistance measurement: Measurement with 3-pole method
- Insulation resistance measurement: Test voltage 100 V, 250 V, 500 V
MPI-506

- Measurement of short circuit loop impedance in networks with rated voltage: 220/380 V, 230 V/400 V, 240/415 V and frequency 45…65 Hz, operating voltage range: 180…460 V
- Testing of prompt, short-delay and selective RCDs with rated current values 10, 15, 30, 100, 300, 500 mA
- Insulation resistance measurement: Test voltage 100 V, 250 V, 500 V
MPI-506

- Measurement of short circuit loop impedance in networks with rated voltage: 220/380 V, 230 V/400 V, 240/415 V and frequency 45…65 Hz, operating voltage range: 180…460 V
- Testing of prompt, short-delay and selective RCDs with rated current values 10, 15, 30, 100, 300, 500 mA
- Insulation resistance measurement: Test voltage 100 V, 250 V, 500 V
MPI-502

- Measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, 230 V/400 V, 240/415 V and frequency 45…65 Hz,
- Testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,
- Detection of the replacement L & N in the socket and automatic conversion.