2.Heating
While you apply the heat to the component, the surrounding
elements are protected
Connecting an external thermocouple provides a high-precise
close-loop control of the component/PCB during the rework process or
can also be used to protect a component or a specific area of the PCB.
As all the JBC Stations, the TESE has a menu
with more than 10 parameters to
customise the control unit.
Specification | |
Nominal power | 300W |
Selectable temperature | 150 to 450°C / 300 to 840°F |
Air flow regulation | 2 to 17 SLPM |
Vacuum | 30% / 228 mmHg / 9 inHg |
Profiles | 25 (up to 10 steps for each), 1 preset profile |
Type K TC connector | 1 for Control & Protection |
ESD safe | Meet ANSI / ESD S20.20-2021 |
Equipotential bonding | Connection to EPA |
USB-A | Firmware update Graphics and profiles |
USB-B | PC communications |
Pedal Connector | Tool control |
Weight and Dimensions | |
Control Unit | 232 x 148 x 160 mm / 4.72 kg. 9.1 x 5.8 x 6.3 in / 10.41 lb. |
Package | 490 x 485 x 278 mm / 5.68 kg. 19.2 x 19.1 x 10.9 in / 12.52 lb. |
TESE is a precision hot air station capable of reworking small and
medium SMDs. The combination of the exclusive JBC hot air system with
protectors, tripods and extractors ensures desoldering components easily
and safety,
concentrating the heat on the selected component as show:
Desoldering with TE Precision Hot Air Station
1. Placing
Choose the extractor, or protector and tripod, which best fits
the component.
3. Extracting
Automatic withdrawal of the desoldered component.
TESE is a precision hot air station capable of reworking small and
medium SMDs. The combination of the exclusive JBC hot air system with
protectors, tripods and extractors ensures desoldering components easily
and safety,
concentrating the heat on the selected component as show:
Desoldering with TE Precision Hot Air Station
1. Placing
Choose the extractor, or protector and tripod, which best fits
the component.
2.Heating
While you apply the heat to the component, the surrounding
elements are protected
3. Extracting
Automatic withdrawal of the desoldered component.
Connecting an external thermocouple provides a high-precise
close-loop control of the component/PCB during the rework process or
can also be used to protect a component or a specific area of the PCB.
As all the JBC Stations, the TESE has a menu
with more than 10 parameters to
customise the control unit.
Specification | |
Nominal power | 300W |
Selectable temperature | 150 to 450°C / 300 to 840°F |
Air flow regulation | 2 to 17 SLPM |
Vacuum | 30% / 228 mmHg / 9 inHg |
Profiles | 25 (up to 10 steps for each), 1 preset profile |
Type K TC connector | 1 for Control & Protection |
ESD safe | Meet ANSI / ESD S20.20-2021 |
Equipotential bonding | Connection to EPA |
USB-A | Firmware update Graphics and profiles |
USB-B | PC communications |
Pedal Connector | Tool control |
Weight and Dimensions | |
Control Unit | 232 x 148 x 160 mm / 4.72 kg. 9.1 x 5.8 x 6.3 in / 10.41 lb. |