TESE Station Precision Hot Air

2.Heating

While you apply the heat to the component, the surrounding elements are protected



Connecting an external thermocouple provides a high-precise close-loop control of the component/PCB during the rework process or can also be used to protect a component or a specific area of the PCB.

As all the JBC Stations, the TESE has a menu with more than 10 parameters to customise the control unit.

Specifications
Specification
Nominal power 300W
Selectable temperature 150 to 450°C / 300 to 840°F
Air flow regulation 2 to 17 SLPM
Vacuum 30% / 228 mmHg / 9 inHg
Profiles 25 (up to 10 steps for each), 1 preset profile
Type K TC connector 1 for Control & Protection
ESD safe Meet ANSI / ESD S20.20-2021
Equipotential bonding Connection to EPA
USB-A Firmware update Graphics and profiles
USB-B PC communications
Pedal Connector Tool control
Weight and Dimensions
Control Unit 232 x 148 x 160 mm / 4.72 kg.
9.1 x 5.8 x 6.3 in / 10.41 lb.
Package 490 x 485 x 278 mm / 5.68 kg.
19.2 x 19.1 x 10.9 in / 12.52 lb.
Description

TESE is a precision hot air station capable of reworking small and medium SMDs. The combination of the exclusive JBC hot air system with protectors, tripods and extractors ensures desoldering components easily and safety, concentrating the heat on the selected component as show:

Desoldering with TE Precision Hot Air Station

1. Placing

Choose the extractor, or protector and tripod, which best fits the component.



3. Extracting

Automatic withdrawal of the desoldered component.

Description

TESE is a precision hot air station capable of reworking small and medium SMDs. The combination of the exclusive JBC hot air system with protectors, tripods and extractors ensures desoldering components easily and safety, concentrating the heat on the selected component as show:

Desoldering with TE Precision Hot Air Station

1. Placing

Choose the extractor, or protector and tripod, which best fits the component.



2.Heating

While you apply the heat to the component, the surrounding elements are protected



3. Extracting

Automatic withdrawal of the desoldered component.



Connecting an external thermocouple provides a high-precise close-loop control of the component/PCB during the rework process or can also be used to protect a component or a specific area of the PCB.

As all the JBC Stations, the TESE has a menu with more than 10 parameters to customise the control unit.

Specifications
Specification
Nominal power 300W
Selectable temperature 150 to 450°C / 300 to 840°F
Air flow regulation 2 to 17 SLPM
Vacuum 30% / 228 mmHg / 9 inHg
Profiles 25 (up to 10 steps for each), 1 preset profile
Type K TC connector 1 for Control & Protection
ESD safe Meet ANSI / ESD S20.20-2021
Equipotential bonding Connection to EPA
USB-A Firmware update Graphics and profiles
USB-B PC communications
Pedal Connector Tool control
Weight and Dimensions
Control Unit 232 x 148 x 160 mm / 4.72 kg.
9.1 x 5.8 x 6.3 in / 10.41 lb.
Package 490 x 485 x 278 mm / 5.68 kg.