The MSO2000 series is a 3-in-1 (logic + protocol + oscilloscope)
analyzer with 16 channels, and each channel supports simultaneous
measurement of analog and digital signals . When measuring power
management-related protocols , it can not only decode the protocol
but also simultaneously To record voltage values , the MSO2000
series currently provides two different signal and bus analysis
modes: logic analyzer mode & protocol analyzer mode.
In the past, many users had questions or did not understand the
voltage level (Threshold) setting in logic analyzers. Therefore,
Acute added a one-click voltage level automatic detection and
setting function to the MSO2000 series products to save users the
time of setting. required time.
Digital specifications | |
power supply | USB bus-power (+5V) |
Static power consumption | <6W< /td> |
Instantaneous maximum power consumption | <6W |
Transmission interface | USB 3.0 |
Timing analysis (asynchronous, highest sampling rate) | 2GHz |
Status analysis (synchronization, external clock) | 200MHz |
Data storage method | Traditional timing, transition timing |
aisle | 16 |
total memory | 4GB |
Timing analysis | Number of available channels (traditional timing/transition timing) - memory per channel |
2GHz timing [number of channels available] - memory per channel | [8/7] - 512Mb |
1GHz timing [number of channels available] - memory per channel | [16/14] - 256Mb |
500MHz timing [number of channels available] - memory per channel | [16/16] - 256Mb |
250MHz timing [number of channels available] - memory per channel | [16/16] - 256Mb |
Inter-channel phase error | < 1ns |
Input voltage channel | N/A |
Input voltage impedance | 1MΩ//2pF |
Non-maximum destructive withstand voltage | over ±42V DC & AC |
Input voltage operating range | ±20V / ±10V (general/high resolution) |
Input voltage sensitivity | 200MHz (1Vpp) |
Trigger voltage group | 2 (CH0~7 & CKI, CH8~15) |
Trigger voltage range | ±20V |
Trigger voltage resolution | 50mV |
Reference voltage accuracy | ±100mV + 5%*Vth |
Trigger resolution | 500ps |
Trigger type | Channel, Label, Single/Multiple Stage, Width, Timeout, Setup/Hold Time Check, External Trigger, Manual |
bus trigger | BiSS-C, CAN2.0B/CAN FD, DALI, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, LPC, MDIO, Mini/Micro LED, MIPI I3C 1.1.1, MIPI RFFE 3, MIPI SPMI 2, Modbus, PMBus, Profibus, SENT, SMBus, SPI, SVI2, UART (RS232), USB PD 3, USB1.1 |
Agreement Analysis | BiSS-C, CAN2.0B/CAN FD, DALI, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MDIO, MIPI I3C 1.1.1, MIPI RFFE 3, Modbus, PMBus, Profibus, PWM, SMBus, SPI , UART (RS232), USB PD 3, USB1.1 |