TID Thermometer Digital
Description

Accurate measurement and easy operation

It is equipped with a high-precision temperature sensor, which allows an easy and repetitive tip-temperature reading.

It works with STD Sensor, which is included, and, additionally, with PH218 Thermocouple Type K.

Using the digital display, you can easily change the temperature units (ºC/ºF).

It also provides special features such as min / max value memory and hold function for an easy and intuitive measurement process.

Product Composition
  • 1 TID Digital
  • 1 STD Sensor for TID
Specifications
  • Measuring range - -65 to +1200 ºC / -85 to +2192 ºF
  • Accuracy - ±0.1% of measuring value
    ±0.1 full scale
  • Cold junction compensation - ±0.3 °C
  • Temperature drift - ±0.01% of measuring value/ K; ±0.025 °C/K
  • Measuring frequency - 3 measurings per second
  • Probe connection - Thermocouple Type K
  • Operating conditions - -25 to 50°C / -13 to 122 ºF
    0 to 80 %RH (non-condensing)
  • Storage temperature - -25 to 70°C / -13 to 158 ºF
  • Power supply- 2x AA
  • Power Requirements - aprox. 1mA, approx. 3mA with blacklight
  • Battery life - Service Life > 2500h with alkaline batteries (without backlight)
  • Battery indicator - 4-stage battery status indicator
    Replacement indicator "BAT"
Weight and Dimensions
  • Accessory - 255 x 210 x 70 mm / 0.77 kg., 10.04 x 8.27 x 2.76 in / 1.69 lb.
  • Package - 280 x 280 x 164 mm / 1.28 kg., 11.02 x 11.02 x 6.46 in / 2.81 lb.
Description

Accurate measurement and easy operation

It is equipped with a high-precision temperature sensor, which allows an easy and repetitive tip-temperature reading.

It works with STD Sensor, which is included, and, additionally, with PH218 Thermocouple Type K.

Using the digital display, you can easily change the temperature units (ºC/ºF).

It also provides special features such as min / max value memory and hold function for an easy and intuitive measurement process.

Product Composition
  • 1 TID Digital
  • 1 STD Sensor for TID
Specifications
  • Measuring range - -65 to +1200 ºC / -85 to +2192 ºF
  • Accuracy - ±0.1% of measuring value
    ±0.1 full scale
  • Cold junction compensation - ±0.3 °C
  • Temperature drift - ±0.01% of measuring value/ K; ±0.025 °C/K
  • Measuring frequency - 3 measurings per second
  • Probe connection - Thermocouple Type K
  • Operating conditions - -25 to 50°C / -13 to 122 ºF
    0 to 80 %RH (non-condensing)
  • Storage temperature - -25 to 70°C / -13 to 158 ºF
  • Power supply- 2x AA
  • Power Requirements - aprox. 1mA, approx. 3mA with blacklight
  • Battery life - Service Life > 2500h with alkaline batteries (without backlight)
  • Battery indicator - 4-stage battery status indicator
    Replacement indicator "BAT"
Weight and Dimensions
  • Accessory - 255 x 210 x 70 mm / 0.77 kg., 10.04 x 8.27 x 2.76 in / 1.69 lb.
  • Package - 280 x 280 x 164 mm / 1.28 kg., 11.02 x 11.02 x 6.46 in / 2.81 lb.