PCS-1000I high
precision AC and DC shunt meter can simultaneously measure current
and voltage with the maximum 6 1/2 measurement resolution.
GW Instek rolls out the new PCS-1000I isolated output high
precision current shunt meter, which inherits the simultaneous
voltage and current measurement function of PCS-1000. PCS-1000I
adopts five sets of independent shunt resistors to provide five
current measurement levels, including300A,30A,3A, 300mA, and 30mA to
meet the requirements of different current level measurements.
Internally, PCS-1000I utilizes two sets of 24bits ADCs and low
temperature coefficient electronic components to mainly focus on the
current measurement of power supply devices. High precision
PCS-1000I can be used in adjusting and calibrating instruments.
Additionally, temperature variation will not cause PCS-1000I to
yield any measurement errors. PCS-1000I can automatically select
optimal measurement level with the maximum resolution so as to
replace manual selection to save operational time.
PCS-1000I provides a BNC output, which can connect with an
oscilloscope to directly observe current waveform variation without
using a current probe. General oscilloscopes do not have isolated
channels and their input and output are structured at a common
point, therefore, the output load will likely result in measurement
errors. PCS-1000I’s isolated current output design can prevent
measurement errors from an oscilloscope with non-isolated outputs.
PCS-1000I, a high precision AC/DC current shunt meter, not only
provides USB and GPIB communications interfaces for users to
remotely control the instrument but also conducts simultaneous voltage and current measurements. The SCPI communications commands of PCS-1000I allow users to remotely control PCS-1000I via a PC to operate measurement data readbacks.
PCS-1000I high
precision AC and DC shunt meter can simultaneously measure current
and voltage with the maximum 6 1/2 measurement resolution.
GW Instek rolls out the new PCS-1000I isolated output high precision
current shunt meter, which inherits the simultaneous voltage and
current measurement function of PCS-1000. PCS-1000I adopts five sets
of independent shunt resistors to provide five current measurement
levels, including300A,30A,3A, 300mA, and 30mA to meet the
requirements of different current level measurements. Internally,
PCS-1000I utilizes two sets of 24bits ADCs and low temperature
coefficient electronic components to mainly focus on the current
measurement of power supply devices. High precision PCS-1000I can be
used in adjusting and calibrating instruments. Additionally,
temperature variation will not cause PCS-1000I to yield any
measurement errors. PCS-1000I can automatically select optimal
measurement level with the maximum resolution so as to replace
manual selection to save operational time.
PCS-1000I provides a BNC output, which can connect with an
oscilloscope to directly observe current waveform variation without
using a current probe. General oscilloscopes do not have isolated
channels and their input and output are structured at a common
point, therefore, the output load will likely result in measurement
errors. PCS-1000I’s isolated current output design can prevent
measurement errors from an oscilloscope with non-isolated outputs.
PCS-1000I, a high precision AC/DC current shunt meter, not only
provides USB and GPIB communications interfaces for users to
remotely control the instrument but also conducts simultaneous
voltage and current measurements. The SCPI communications commands
of PCS-1000I allow users to remotely control PCS-1000I via a PC to
operate measurement data readbacks.
PCS-1000I will replace non-isolated output PCS-1000 models, which will be discontinued.