A Solid
Foundation for Reliable, Safe and Practical Safety Compliance
Testing
GW Instek is launching to the market a series of safety tester
(hi-pot tester/hipot tester) with high durability and multiple
user-protection design. The GPT-9800 supports the major test items
among all the needed for the compliance of the safety standards such
as IEC, EN, UL, CSA, GB, JIS and other safety regulations.
A total of 4 safety testers in the GPT-9800 Series, namely GPT-9804,
GPT-9803, GPT-9802 and GPT-9801, are available for various
applications. The GPT-9804 is a 4-in-1 model capable of performing
AC withstanding, DC withstanding, insulation resistance and ground
bond tests. The GPT-9803 is a 3-in-1 model capable of performing AC
withstanding, DC withstanding as well as insulation resistance
tests. The GPT-9802 is capable of performing both AC and DC
withstanding tests, whereas the GPT-9801 is able to perform AC
withstanding test. The series of safety tester is built upon a
high-efficiency PWM amplifier platform with AC 200VA maximum output
capacity to impede the influence from the voltage fluctuation of the
input AC source. This ensures a stable voltage supply for all the
tests of the GPT-9800 Series.
Targeting user’s protections, the GPT-9800 series uses a combination
of hardware and software controls to improve safety: A self-check is
performed to make sure all the functions and operations are under
normal condition each time when the tester is turned on; the Zero
Crossing Turn-On design
imposes the output voltage to always begin at the zero crossing of a sine wave to avoid the impact of surge voltage output; and the output voltage is automatically cut off (within 150μs) when abnormal output voltages have been detected or when the upper or lower current limits have been reached during testing. To protect operator from hazardous injury, the GPT-9800 Series automatically discharges the DUT after test (within 200ms) each time to eliminate excessive voltage that remains on the DUT. To further ensure safety, the interlock connector can also be used as double protections to prevent inadvertent operation.
A Solid Foundation
for Reliable, Safe and Practical Safety Compliance Testing
GW Instek is launching to the market a series of safety tester
(hi-pot tester/hipot tester) with high durability and multiple
user-protection design. The GPT-9800 supports the major test items
among all the needed for the compliance of the safety standards such
as IEC, EN, UL, CSA, GB, JIS and other safety regulations.
A total of 4 safety testers in the GPT-9800 Series, namely GPT-9804,
GPT-9803, GPT-9802 and GPT-9801, are available for various
applications. The GPT-9804 is a 4-in-1 model capable of performing
AC withstanding, DC withstanding, insulation resistance and ground
bond tests. The GPT-9803 is a 3-in-1 model capable of performing AC
withstanding, DC withstanding as well as insulation resistance
tests. The GPT-9802 is capable of performing both AC and DC
withstanding tests, whereas the GPT-9801 is able to perform AC
withstanding test. The series of safety tester is built upon a
high-efficiency PWM amplifier platform with AC 200VA maximum output
capacity to impede the influence from the voltage fluctuation of the
input AC source. This ensures a stable voltage supply for all the
tests of the GPT-9800 Series.
Targeting user’s protections, the GPT-9800 series uses a combination
of hardware and software controls to improve safety: A self-check is
performed to make sure all the functions and operations are under
normal condition each time when the tester is turned on; the Zero
Crossing Turn-On design imposes the output voltage to always begin
at the zero crossing of a sine wave to avoid the impact of surge
voltage output; and the output voltage is automatically cut off
(within 150μs) when abnormal output voltages have been detected or
when the upper or lower current limits have been reached during
testing. To protect operator from hazardous injury, the GPT-9800
Series automatically discharges the DUT after test (within 200ms)
each time to eliminate excessive voltage that remains on the DUT. To
further ensure safety, the interlock connector can also be used as
double protections to prevent inadvertent operation.
The GPT-9800 Series,
equipped with a simple & clear panel layout, a high resolution dot
matrix LCD display, and color LED indicators, allows operators to
interpret measurement results easily and quickly. All major test
functions, including AC withstanding (AC 5kV/40mA), DC withstanding
(DC 6kV/10mA), insulation resistance (DC 50V ~ 1000V) and ground
bond (AC 30A max.) tests, are performed under a high-stability
voltage output with high-resolution measurement results. Further
more, the test duration, ramp up time and upper/lower limits of the
output voltage are fully-adjustable to accommodate a wide variety of
safety tests with accurate measurement results.
Other functions and features of the GPT-9800 include: open circuit
detection for ground bond testing to get correct measurement result
with confidence; 100 sets of memory to save panel settings, which
can be recalled for single test individually or for automatic tests
in sequence; a remote output on-off terminal in the front panel and
a signal I/O port in the rear panel provided as the means for remote
start/stop control of the safety tester; RS-232C, USB and GPIB
(optional) interfaces available for PC remote control and test
result logging.