GOM-804/805
feature
3.5-inch TFT display, maximum 50,000 counts measurement display, the
rapid sampling rate of 60 readings per second, optimum 0.05%
measurement precision, four wire measurement method as well as the
temperature measurement and temperature compensation measurement
function to meet the requirement of low resistance measurement
application. The GOM-805 also includes various drive modes and Dry
circuit for contact resistance measurement applications. More
features, including 20 sets of panel setting memory and many
external control interface such as RS-232C, USB, Handler/Scan/EXT IO
or GPIB (option), greatly elevate GOM-804/805 milliohm meter’s
convenience on practical applications.
GOM-804/805 adopt 3.5-inch color LCD to enhance the clarity of
measurement results and to provide display for related setting
criteria that tremendously brings up the completeness of test
information. Additionally, GOM-804/805, with the optimum 0.05%
precision, augment the measurement speed to 60 sampling rate per
second and maintain the display digits of five instead of four
despite of different speed selections. Furthermore, the independent
functionality keys and direction keys together increase the
operational convenience which allows users to complete their
measurement tasks with intuitive convenience and speed.
GOM-805 provides Dry circuit and various drive modes (DC+, DC-,
Pulsed, PWM) for measurement applications on different materials.
The pulsed current output mode is suitable for interacting
conductors of different materials and this output mode is to reduce
the thermal EMF influence,
which is caused by electric potential difference generated from different conductors acting on different temperatures while conducting low resistance measurements. The DC+ and DC- output modes are best for the measurement requirements of inductive components. The PWM output mode, ideal for changing temperature sensitive materials, can avoid resistance value variation which is due to over load happened on current measurement for a long period of time. During the DC+, DC- and Pulsed drive is supplied; the Dry circuit can work with them also. Dry circuit can limit the applied voltage under the open circuit voltage of 20mV to avoid over voltage occurred on the both ends of components. The over voltage will damage the oxide coating and the thin layer of contact surface, as a result, the validity of measurement will then be ruined. For instance, contact resistance of connector measurement is one of the applications.
GOM-804/805
feature
3.5-inch TFT display, maximum 50,000 counts measurement display, the
rapid sampling rate of 60 readings per second, optimum 0.05%
measurement precision, four wire measurement method as well as the
temperature measurement and temperature compensation measurement
function to meet the requirement of low resistance measurement
application. The GOM-805 also includes various drive modes and Dry
circuit for contact resistance measurement applications. More
features, including 20 sets of panel setting memory and many
external control interface such as RS-232C, USB, Handler/Scan/EXT IO
or GPIB (option), greatly elevate GOM-804/805 milliohm meter’s
convenience on practical applications.
GOM-804/805 adopt 3.5-inch color LCD to enhance the clarity of
measurement results and to provide display for related setting
criteria that tremendously brings up the completeness of test
information. Additionally, GOM-804/805, with the optimum 0.05%
precision, augment the measurement speed to 60 sampling rate per
second and maintain the display digits of five instead of four
despite of different speed selections. Furthermore, the independent
functionality keys and direction keys together increase the
operational convenience which allows users to complete their
measurement tasks with intuitive convenience and speed.
GOM-805 provides Dry circuit and various drive modes (DC+, DC-,
Pulsed, PWM) for measurement applications on different materials.
The pulsed current output mode is suitable for interacting
conductors of different materials and this output mode is to reduce
the thermal EMF influence, which is caused by electric potential
difference generated from different conductors acting on different
temperatures while conducting low resistance measurements. The DC+
and DC- output modes are best for the measurement requirements of
inductive components. The PWM output mode, ideal for changing
temperature sensitive materials, can avoid resistance value
variation which is due to over load happened on current measurement
for a long period of time. During the DC+, DC- and Pulsed drive is
supplied; the Dry circuit can work with them also. Dry circuit can
limit the applied voltage under the open circuit voltage of 20mV to
avoid over voltage occurred on the both ends of components. The over
voltage will damage the oxide coating and the thin layer of contact
surface, as a result, the validity of measurement will then be
ruined. For instance, contact resistance of connector measurement is
one of the applications.
With respect to
connecting the external control, GOM-804/805 provide a D-sub 25-pin
combined interface to execute, according to the functionalities,
Handler, Scan or EXT IO for respectively connecting to a sorting
machine; connecting to an external on-off switch, and directly
conducting external trigger control. For remote control and
measurement result retrieval requirements, GOM-804/805 also provide
various interface selections such as RS-232C, USB, and GPIB
(GOM-804(option)/GOM-805(standard) interface. Furthermore, the
control commands are compatible to that of GOM-802 that saves time
in adjusting programs while switching from the old model to the new
model.
To sum up, GOM-804 evolves from GOM-802 platform with more advanced
functionalities and specifications, including display digits,
measurement speed and standard interface (RS-232C/USB). With all the
capabilities of GOM-804, GOM-805 augments itself with new
measurement abilities (Dry circuit and various drive modes) to meet
the requirements of broader low resistance measurement applications.