Features
  • Support UFS 2.1 Gen 3, Rate A/B, up to 5.8Gbps per lane, 2 Lanes
  • Supports MIPI M-PHY UFS2.1, Up to 5.8Gbps per lane, 2 Lanes
  • Can display Unipro and UFS2.1 protocol packet data in table format, including command parsing
  • Uses 32Gb RAM with hard disk serial Stream to store Unipro and UFS communication data, which can completely record the process of initialization of the object under test from Low Power Mode to High Speed Mode​
  • Provide Data Filter function, which can filter out unnecessary data to save memory
  • Provide Search data function
  • Provides CRC Packet calculation and error display
  • Unipro, UFS command statistics function, including total number of packets, number of instructions of each type, and error number statistics
  • Unipro, UFS command trigger function
Features
  • Support UFS 2.1 Gen 3, Rate A/B, up to 5.8Gbps per lane, 2 Lanes
  • Supports MIPI M-PHY UFS2.1, Up to 5.8Gbps per lane, 2 Lanes
  • Can display Unipro and UFS2.1 protocol packet data in table format, including command parsing
  • Uses 32Gb RAM with hard disk serial Stream to store Unipro and UFS communication data, which can completely record the process of initialization of the object under test from Low Power Mode to High Speed Mode​
  • Provide Data Filter function, which can filter out unnecessary data to save memory
  • Provide Search data function
  • Provides CRC Packet calculation and error display
  • Unipro, UFS command statistics function, including total number of packets, number of instructions of each type, and error number statistics
  • Unipro, UFS command trigger function
Scheme name UFS2.1
Tip name UFS-tip/End-tip
Channel combination 4+2 (Data+Analog) / 1-Diff. (Differential signal)
Trigger voltage (Data) range -0.5V ~ +4.8V / -
Trigger voltage (Data) resolution 21mV/-
Trigger voltage (Data) accuracy ±100mV + 5% *Vth / -
Input voltage (Data) Non-maximum destructive withstand voltage ±15V DC+AC peak / ±10V
Input voltage (Data) working range -1V ~ 8V / 0 ~ 5V
Input voltage (Data) Sensitivity ~300mV / ~200mVpp
Input impedance(Data) 1MΩ || 5pF / 250Ω
Input voltage (Analog) non-maximum destructive withstand voltage -0.5V ~ +8V DC+AC peak / -
Input voltage (Analog) working range 0V~4V/-
Input voltage (Analog) resolution ~1mV/-
Input voltage (Analog) Sampling rate 1M/-
Input impedance(Analog) 1MΩ || 100pF/-