Automotive Charger and Battery Test Solutions

 
 

 
 
PEL-5000C Series
High Power DC Electronic Load
   
Maximum Power up to 192kW
 
Up to 8 units of Master/Slave Parallel Control
 
5-digit Digital Voltage, Current and Power Meter
 
Large LCD Display
 
Display Voltage Value, Current Value, Watt Value at the Same Time
 
Suitable for Power Factor Regulator (PFC) Testing (600V, 1200V Models)
 
Automatically Perform OCP, OPP Test
 
The Power-on State Value Can be Set Constant Current,
Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Power + Constant Voltage, Dynamic and Short Circuit Modes
 
Short Circuit Time Can be Set During Short Circuit Test
 
Over Current, Over Power, Over Temperature Protection and Over Voltage Warning
 
Voltage Polarity Display Can be Set to Positive Value ("+") or Negative Value ("-")
 
Support Solar Panel MPPT Test
 
Optional Interface: GPIB, RS232, USB, LAN
AEL-5000 Series
AC & DC Electronic Load
   
Turbo Mode (Multiplier Mode) Can Withstand up to 2 Times the Rating Current and Power of the Electronic Load in a Short Period of Time
 
Operating Mode: CC, linear CC, CR, CV, CP and AC Rectifier Loads
 
Measurement Items: Voltage Value(Vrms, Vpeak, Vmax., Vmin), Current Value(Irms, Ipeak, Imax., Imin.), Watt Value, Volt-ampere Value(VA), Frequency Value, Crest Factor, Power Factor, Voltage Total Distortion(V THD, VH), Current Total Distortion (ITHD, IH), Etc
 
Eight Units Connected in Parallel up to 180kW for Single-phase and 540kW for Three-phase
 
Support Loading and Unloading Angle Control, Loading and Unloading Angle Control Can be set at the Full Range of 0-359 Degrees
 
Support Positive Half Cycle or Negative Half Cycle Load
 
Support SCR/TRIAC Current Phase Modulation Waveform, 90-degree Trailing Edge and Leading Edge
 
Support the Capacitive Load (Inrush Current) when the Power Supply is Turned on and the Transient Current (Surge Current) Test when the Load is Suddenly Connected (Hot Plug-in) During Operation
 
Crest Factor Range: 1.414~5.0
 
Power Factor Range: 0.1~1.0 Leading or Trailing
 
Frequency Range: DC, 40~440Hz(AEL-5003-480-18.75/AEL-5004-480-28: DC, 40~70Hz), and 800Hz and 1kHz Need to be Customized
 
Optional Control Interfaces: GPIB, RS-232, USB, LAN

Industries  Products  |  Partners  |  Support  |  About  |  Contact Us

     
   
     
  Integrated Services and Consultancy
(An ESA Group Associate)
#37, Second Floor, "Embedded Home", 36th Cross, II Block, Rajajinagar Bengaluru-560010, Karnataka, India

Phone No.: +91-80-23420746, 23521165, 23126100
Sales:
sales@isc4esaindia.com
Support:
support@isc4esaindia.com
Service: service@isc4esaindia.com
 
     